views
Utilizing a Furnace Reset
Place a container under the bleeder pipes, if necessary. If your furnace has a reset function, there should be two copper lines running from your oil tank to the pump. If your pump does not have pipes, the oil may bleed from a fixture. You may need to put a container underneath this fixture to catch bleeding oil.
Press the reset button. Some furnaces may not be equipped with a reset button. However, if yours has this feature, you should find it located on the furnace, usually close to the oil tank. In most cases, this button is red. Push it once or twice. If you cannot easily locate the reset button on your furnace, consult its user instructions. This part should be described or clearly marked on diagrams.
Check fuses and breakers when the furnace doesn't light. If the furnace doesn't come on in 60 seconds after pressing the reset, check the furnace fuses and circuit breaker. Replace or reset necessary fuses. Try to reset the furnace one more time. If the furnace does not relight, bleed the fuel line as described. When your furnace is running, a lack of oil spray on the inside of the furnace is another indication that you need to bleed the fuel line.
Readying the Bleeder Valve
Gather your supplies. You may have some of these supplies already in your household. Those you are lacking can be bought at your local hardware store or home center. To bleed your furnace you'll need: ¼ in (.64 cm) flexible tubing Container (like a coffee can or a liter soda bottle, to catch oil) Oil absorbent material (like sand, non-clumping clay, or cat litter) Rag (to wipe up excess oil) Suitable wrench (generally 3/8th's size)
Turn off your furnace. There should be a toggle switch on the furnace for this. Toggle the furnace to "Off." The reset button may have automatically turned off your furnace. If so, this is usually indicated by a red "On" light next to the reset button. When the auto-shut off for the reset button is engaged, you don't need to turn the main On/Off toggle switch to "Off."
Locate the bleeder valve. This is generally positioned on the side of the fuel pump, usually at 4 or 8 o'clock position. The bleeder looks like a grease fitting with hex nut shape, like one that a ⁄8 inch (1.0 cm) wrench might fit. You should find fuel lines leading to and from the fuel pump. The pump is oftentimes located on the left side of the burner unit.
Attach nylon tubing to the bleeder. Place your container on the floor close to the bleeder. Fit the tubing over the bleeder so it hangs down. The tubing should extend to the bottom of your container. This container will be used to catch the oil. Choose an oversized rather than undersized container. Oil that overflows your container can make a big mess. Use a clean, dry container for bleeding oil from the pump of your furnace. This way, you'll be able to return and re-use the oil after it is drained. Draining the fuel line for your furnace can be messy work. You may want to wear a pair of gloves while bleeding oil.
Loosen the bleeder. After the tubing is attached to the bleeder, prepare the bleeder by loosening it with a wrench. Turn it counterclockwise to do so. Once broken loose, lightly re-tighten the bleeder with your hands. During this process you might hear a gurgling noise from the tubing. This is completely natural.
Bleeding the Fuel Line and Restarting the Furnace
Turn on the furnace and open the bleeder. Toggle your furnace from "Off" to "On." Immediately after doing so, open the bleeder valve a half turn counterclockwise. The tubing should eject a combination of oil and air. The force of oil and air running through the tubing can cause it to move. You or a helper may want to hold the tubing and container to prevent accidental spills. It may be necessary to use the reset button to turn on the furnace. Follow your furnace's user instructions for best results. Opening the bleeder valve more or less will increase or decrease the rate at which the oil drains. Adjust this as necessary for your situation. The bleeder screw may have to be completely removed to get a good flow. Shut the furnace off once the flow has started. Replace the screw and restart furnace when through bleeding.
Resolve locked out reset buttons, if necessary. If you've hit your reset button multiple times, a safety lock out feature may be preventing you from pressing it again. To restore the reset button, press and hold it for 35 seconds, then release.
Bleed the line until only fuel comes out. After a few seconds, the bleeder should begin to expel an uninterrupted flow of oil. Allow the line to drain a few seconds after this to ensure all air has been removed. Close the bleeder by turning it clockwise until firm. In some cases, especially if the pump is far from the oil tank, you may need to bleed your line into your container several times until all the air is removed from it. If there is no discharge from the bleeder, there may be a problem with the pump, a clog in the filter, or damage somewhere in the fuel line preventing it from draining. Fuel that has been drained into a clean, dry container can be returned to the fuel tank after it has been drained.
Check the burner for ignition. The bleeder valve should be returned to the fully closed position you found it in. The furnace should be switched to the "On" position. At this point, the furnace should relight. If the furnace is operating properly, you should be able to view an orange glow or fire through the inspection port located on the front of the furnace. If your furnace does not relight, drain the line again as described. You may have to bleed the line several times before it begins working again.
Troubleshooting Your Furnace
Verify the condition of oil supply lines. Crushed, bent, or damaged tubing supplying your furnace with oil may be starving it of fuel. Leaking lines may prevent oil from reaching the burner. Brittle, deformed, leaking, or degraded tubing should be replaced. Tubing for your furnace can be purchased at most hardware stores and home centers. When replacing tubing, your furnace should be turned off. Oil remaining in tubing can make a big mess when being replaced. Lay newspaper, a drop cloth, and/or a container beneath tubing you're changing to prevent a mess.
Bleed air from the oil filter. If your furnace doesn't restart after bleeding the fuel line, you may need to remove air from the filter. The oil filter is usually found suspended close to the fuel line either near the oil tank or furnace. To bleed the oil filter: Carefully loosen the ⁄4 inch (0.6 cm) bolt on the top of the filter with an appropriate wrench until you hear air escape. Stop loosening when you hear air. Let the air drain. When oil begins to bubble around the bolt, tighten it closed to the position you found it.
Replace your oil filter, if necessary. Clogged filters can also prevent your furnace from restarting. Filter kits for your oil furnace are available at most home supply stores. Different furnaces will have different filter replacement procedures. Follow the user instructions for your furnace to properly replace the filter. Replacement kits generally come with new seals and gaskets for the bolts of the filter. Use these new parts for the best results. When reassembling your filter, it's especially important to make sure that all the fixtures and fastenings are snug and tight.
Call a professional, if necessary. Bacteria or sludge may be clogging the lines of your furnace. This may require a burner technician, who can blow out and clear the lines. Look for contact information for technicians certified to work on your furnace in its user instructions.
Comments
0 comment